ASW-WP Installation Guide
Display Control Commands
Description
Command
Response
Turn Display Control ON
DFG1<CR><LF>
No response
Turn Display Control OFF
DFG0<CR><LF>
No response
Store the ON command for
Display Control (
xx = up to 20
characters)
DON(xx)<SP><CR><LF>
Example:
DONpwron<SP><CR><LF>
No response
Store the OFF command for
Display Control (
xx = up to 20
characters)
DOF(xx)<SP><CR><LF>
Example:
DOFpwroff<SP><CR><LF>
No response
Store the input select command
for Display Control (xx = up to 20
characters)
DIS(xx)<SP><CR><LF>
Example:
DIShdmi1<SP><CR><LF>
No response
Store the time between power
on and input select commands
(xxx = time in seconds 3
characters)
DDC(xxx)<CR><LF>
Example for 5 sec.:
DDC005<CR><LF>
No response
Store the “No signal” timeout
value (xxx = time in minutes 3
characters)
DNS(xxx)<CR><LF>
Example for 30 min.:
DNS030<CR><LF>
No response
Disable the “No signal” timeout
DNS000<CR><LF>
No response
Store the “No activity” timeout
value (xxx = time in hours 3
characters)
DNA(xxx)<CR><LF>
Example for 3 hours:
DNA005<CR><LF>
No response
Disable the “No activity” timeout
DNA000<CR><LF>
No response
Store the display baud rate
DBR(x)<CR><LF>
Where:
1 = 115200
2 = 57600
3 = 19200
4 = 9600
No response
16